LYN Series Communication Signal Isolator

Suitable for RS485 communication devices, providing physical isolation of the 485 differential signal.
View Details +

LYA-R Thermocouple Isolation Safety Barrier

The LYA-R series thermocouple isolation safety barrier primarily serves to receive thermocouple signals from hazardous areas on-site, isolates and converts them, and then transmits the signals to control systems or other combined instruments located in safe areas. It prevents hazardous signals from entering the hazardous environment via the intrinsically safe terminals, while also ensuring electrical, input, and output circuits remain completely isolated from one another.
View Details +

LYA-Z Thermal Resistance Isolation Safety Barrier

The LYA-R series thermocouple isolation safety barrier primarily serves to receive thermocouple signals from hazardous areas on-site, isolates and converts them, and then transmits the signals to control systems or other combined instruments located in safe areas. It prevents hazardous signals from leaking back into the hazardous area via the intrinsically safe terminals, while also ensuring complete electrical isolation among the power supply, input, and output circuits.
View Details +

LYA-C Operation Terminal Isolation Safety Barrier

The LYA-C series operator-isolated safety barrier primarily functions by receiving the 4–20mA signal from controllers or operators located in the safe area, isolating and converting it before outputting, thereby driving field-mounted actuators. It also prevents hazardous signals from entering the potentially explosive environment via the intrinsically safe terminals, while ensuring complete electrical isolation among the power supply, input, and output circuits.
View Details +

LYW-...G Series Passive Signal Isolator

Suitable for situations where it is inconvenient to provide separate power on-site, requiring isolation of on-site equipment and systems to enhance the system's resistance to interference.

Application 1: Receive the current signal output from the four-wire transmitter on-site, isolate it, and then output it to the system;

Application 2: Alternatively, receive the current signal output by the system, isolate it, and then send it to the field-mounted valve positioner or electrical converter.

In both application modes, the energy consumption during operation comes entirely from the input circuit.

View Details +

LYJ Series AC Signal Isolator

The primary function of the LYJ series AC signal isolators is to isolate and convert the input power-frequency voltage or current signal into a standard DC current or DC voltage signal required by the user, while ensuring electrical isolation among the power supply, input, and output.
View Details +

LYK Series Digital Signal Isolator

Suitable for receiving switch or proximity switch inputs from the field, with isolated output relay contacts. Each channel can be independently configured for either in-phase or out-of-phase control of input and output, and it also features an input line fault detection and alarm indication function.
View Details +

LYD Series Linear Resistance Isolator

Suitable for signal input of linear resistive potentiometers such as field-position potentiometers and angle potentiometers, converting them into standard current/voltage signals before transmitting to PLC/DCS systems. Resolving the following scenario issues:

① Signal interference between instruments and systems, leading to data instability.

② The interface signals between the instrument and the system differ, requiring signal conversion.

③ One-way signal transforms into multiple signals, supplying automated instruments and control systems.

View Details +

LYA-J Detection Terminal Isolation Safety Barrier

The LYA-J series isolation safety barrier primarily serves to provide isolated intrinsically safe power voltage to transmitters located in hazardous areas, while also isolating and converting the 4–20mA signals generated by the transmitters before transmitting them to control systems or other combined instruments in safe areas. It ensures that hazardous signals cannot leak from the intrinsically safe terminals into the hazardous environment, and it maintains electrical isolation among the power supply, input, and output circuits.
View Details +

LYG-...1 Series Signal Isolators

Suitable for scenarios where signal transmission between automation instruments, control systems, and actuator structures leads to mutual interference, causing system instability and erratic data fluctuations. It is also ideal for situations where signals from different devices or instruments need to be converted to ensure compatibility. Additionally, this solution excels in cases where a single signal needs to be split into multiple channels, each routed to separate devices. ⚪ Addressing loop interference caused by multi-point grounding. ⚪ Addressing electromagnetic interference and the intrusion of higher harmonic signals. ⚪ Provides isolated power to the field transmitter and collects loop current signals for the downstream system. ⚪ Applicable on-site equipment: two-wire transmitters, three-wire transmitters, and current source signals
View Details +

LYW-...P Series Passive Power Distribution Isolator

Suitable for scenarios where signal transmission between automation instruments, control systems, and actuation structures leads to mutual interference, causing system instability and erratic data fluctuations. Also ideal for situations where signals from different devices or instruments need to be converted to match each other. For example, when a single signal needs to be split into multiple channels, each sent to separate devices. ⚪ Addressing loop interference caused by multi-point grounding. ⚪ Addressing electromagnetic interference and the intrusion of high-order harmonic signals. ⚪ Provides isolated power to the field transmitter and collects loop current signals for the downstream system. ⚪ Applicable field devices: Two-wire transmitters, three-wire transmitters, current source signals
View Details +

LYT Series Temperature Signal Isolator

Suitable for on-site RTD and thermocouple temperature sensors, converting their resistance/mV signals into isolated 4-20mA or similar signals before transmitting them to PLC/DCS systems. Addressing the following scenario challenges:

① Signal interference and data instability between instruments and systems.

② The interface signals between the instrument and the system are different, requiring signal conversion.

③ One-way signal transforms into multiple signals, supplying automated instruments and control systems.

View Details +